亚洲精华国产精华液,欧美吧,啊灬啊别停灬用力啊村妇,国产精品无码久久av

天津市電纜總廠橡塑電纜廠
13

13731622776

當(dāng)前位置:天津市電纜總廠橡塑電纜廠>>低壓電力電纜>>YJLV低壓鋁芯電力電纜>> 鋁芯鎧裝高壓電纜-YJLV22-10千伏-3*120

鋁芯鎧裝高壓電纜-YJLV22-10千伏-3*120

參  考  價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)

品       牌小貓牌

廠商性質(zhì)生產(chǎn)商

所  在  地廊坊市

更新時(shí)間:2023-08-17 17:19:06瀏覽次數(shù):836次

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 食品機(jī)械設(shè)備網(wǎng)

郝進(jìn)生

銷售部經(jīng)理
掃一掃,微信聯(lián)系
同類優(yōu)質(zhì)產(chǎn)品更多>
鋁芯鎧裝高壓電纜-YJLV22-10千伏-3*120產(chǎn)品說(shuō)明信息圖片可能與型號(hào)規(guī)格不太相符,如果您需要更詳細(xì)了解本產(chǎn)品的相關(guān)信息可以索取相關(guān)資料或致電

鋁芯鎧裝高壓電纜-YJLV22-10千伏-3*120

本產(chǎn)品按GB12706《額定電壓35V及以下銅芯、鋁芯塑料絕緣電力電纜》標(biāo)準(zhǔn)生產(chǎn),同時(shí)還可根據(jù)用戶需要按電工委員會(huì)推薦標(biāo)準(zhǔn)IEC、英國(guó)標(biāo)準(zhǔn)、德國(guó)標(biāo)準(zhǔn)及美國(guó)標(biāo)準(zhǔn)生產(chǎn)。
The product is manufactured according to the standard ofGB12706 or IECBSDIN and ICEA upon request.
適用范圍 Applications
  本產(chǎn)品適用于工頻額定電壓3.6/6kv26/35kv輸配電線路作配送電能子用。
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv26/35kv.
使用特性 Operating characteristics
· 工頻額定電壓U0/U3.6/6kv26/35kv
Rated power-frepuency voltage U0/U: 3.6/6kv26/35kv.
· 電纜導(dǎo)體的zui高允許工作溫度:90
Max.admissible operating temperature of the conductor:90.
· 短路時(shí)(zui長(zhǎng)時(shí)間不超過(guò)5s)電纜導(dǎo)體的zui高溫度不超過(guò)2500C
Max. short-circurt temperature of conductor shall not exceed 2500C.
(5s maximum duration)
· 電纜敷設(shè)時(shí)環(huán)境溫度應(yīng)不低于00C
The ambient temperature under installation should not below 00C.
· 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a single-core cable should not less than 15 times of the cable diameter.
電纜額定電壓的選擇 Voltage designation
· 電纜的額定電壓應(yīng)適合于電纜系統(tǒng)的運(yùn)行狀況,用U0/UUmkv表示。
U0-電纜設(shè)計(jì)用的導(dǎo)體對(duì)地或金屬屏蔽之間的額定工頻電壓;
U-電纜設(shè)計(jì)用的導(dǎo)體間的額定工頻電壓;
Um-設(shè)備可承受的zui高系統(tǒng)電壓"的zui大值。
The rated voltage of the cable for a given applixation shall be suitable for the operating conditions
in the system in which the cable is used,and is expressed in the form of U0/UUmkv
Where: 鋁芯鎧裝高壓電纜-YJLV22-10千伏-3*120
U0The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed;
U The rated power-frequency voltage between conductos, for which the cable designed;
UmThe maximum value of thehighest system voltage"for which the equipment may beused.
· 三相系統(tǒng)用電纜的U0值推薦如下表:
The values of U0 recommened for cable to be used in three-phase systems are listed below:

 

U kv

U m kv

U 0 * kv

A B 類系統(tǒng) System categories A and B

C 類系統(tǒng) Systems categories C

6

7.2

3.6

6

10

12

6

8.7

15

17.5

8.7

12

20

24

12

18

30

36

18

35

40.5

21

26

 

A類系統(tǒng)──該類系統(tǒng)任何一相導(dǎo)體與地和接地導(dǎo)體接觸時(shí),能在1min內(nèi)與系統(tǒng)分離
B類系統(tǒng)──該類系統(tǒng)僅包括單相接地故障短時(shí)運(yùn)行的條件,接地故障時(shí)間應(yīng)不超過(guò)1h, 但在任何情況下,zui長(zhǎng)不超過(guò)8h每年接地故障總持續(xù)時(shí)間不超過(guò)125h
C類系統(tǒng)──不屬于A類、B類的系統(tǒng)。
System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min.
System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h.
System categeory C──This category comprises all systems which do not fall into A and B
電纜的型號(hào)Type of cable

型號(hào) Type

名稱 Designation

適用范圍 Application

YJV

銅芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Copper conductor,XLPE insulated and PVC sheathed power cable

室內(nèi)、隧道及電纜溝等場(chǎng)所,不能承受機(jī)械外力。單芯電纜不允許敷設(shè)在磁性管道中。 For laying indoors intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible

YJLY

鋁芯交聯(lián)聚乙烯絕緣乙烯護(hù)套電力電纜 Aluminium conductor, XLPE insulated and PVC sheathed power cable

YJY

銅芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Copper conductor ,XLPE insulated and PEsheathed power cable

YJLY

鋁芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Alumimium conductor ,XLPE

 

產(chǎn)品介紹:高壓交聯(lián)電纜產(chǎn)品具有傳輸容量大,工作溫度,不受落差的限制,安裝敷設(shè)方便等特點(diǎn),廣泛應(yīng)用于工礦企業(yè)和城市電網(wǎng)中。高壓交聯(lián)電纜主要用于電力、建筑、工礦、冶金、交通等部門的動(dòng)力、照明輸配電系統(tǒng),由于聚乙烯是電絕緣性能的塑料,加上經(jīng)過(guò)高分子交聯(lián)后成為熱固性材料,因此其電性能好,機(jī)械性能和耐熱性好。近二十年來(lái),已成為中國(guó)中、高壓電纜的主導(dǎo)品種,產(chǎn)品適用于6——35KV的各個(gè)電壓級(jí)中它可分為:YJV-交聯(lián)聚乙稀絕緣聚氯乙烯護(hù)套電力電纜,YJV22-交聯(lián)聚乙烯絕緣鋼帶鎧裝高壓電纜,YJLV-交聯(lián)聚乙烯絕緣鋁芯鋼帶鎧裝高壓電纜。
執(zhí)行標(biāo)準(zhǔn):GB/T12706-2002
使用特性
· 工頻額定電壓U0/U6kv/10kv26/35kv
· 電纜導(dǎo)體的zui高允許工作溫度:90℃
· 短路時(shí)(zui長(zhǎng)時(shí)間不超過(guò)5s)電纜導(dǎo)體的zui高溫度不超過(guò)2500C
· 電纜敷設(shè)時(shí)環(huán)境溫度應(yīng)不低于00C
· 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。
電纜額定電壓的選擇
· 電纜的額定電壓應(yīng)適合于電纜系統(tǒng)的運(yùn)行狀況,用U0/UUmkv表示。
U0-電纜設(shè)計(jì)用的導(dǎo)體對(duì)地或金屬屏蔽之間的額定工頻電壓;
U-電纜設(shè)計(jì)用的導(dǎo)體間的額定工頻電壓;
Um-設(shè)備可承受的zui高系統(tǒng)電壓"的zui大值。